Platform

One live systems graph that never loses context.

VinciStack builds a live model of your hardware program, linking every requirement, interface, test and decision, and keeps it current as your engineers work. Our agents watch CAD, code, requirements and simulations. When a part changes, they trace what it affects and flag conflicts before anything reaches the factory floor. The reasoning behind each change stays with the graph, iteration after iteration.

Deploys on-premiseNo data leaves your network
Systems graph HX-4 heavy-lift drone · exampleLive

Built for aerospace, drone, robotics and automotive programs

01

Requirements

Manage requirements the way software teams manage code. Every change is proposed, reviewed and merged with its reasons attached, and the full history of who changed what, and why, stays one click away.

Change actions
Propose a requirement change, run checks, get it reviewed by its owner and merge it into the baseline.
← Change actions
Update REQ-THM-011● Open● Approved● Merged
Propulsion lead proposed 1 requirement change · opened just now
Conversation 1Checks 2Requirements changed 1
PL
Propulsion lead opened this change action
Lower the ESC limit after TEST-121 run 7 failed (root cause: HX-2231).
EDITREQ-THM-011
+
Propulsion lead edited REQ-THM-011
◎
Propulsion lead requested review from Systems eng.
✓
Checks passed · impact analysis, linked tests
SE
Systems eng. approved these changesApproved
Checked against DR-4 and the thermal budget.
⑂
MergedPromoted to baseline 4
Import or connect
Bring requirements in from Excel, or keep them synced from Jama Connect and Jira.
Xthermal_reqs_v3.xlsx
Drop a spreadsheet
142 requirements imported · 3 duplicates flagged
Jama Connect
Jira
PolarionConnect
Side-by-side diffs
See exactly which clause changed, down to the value, before anyone approves it.
REQ-THM-011Edited+1 −1Side-by-side · Unified
CURRENT
1WHILE ambient temperature ≥ 40 °C
2THEN the ESC case temperature shall remain ≤ 85 °C
3FOR any continuous hover ≥ 30 s
PROPOSED
1WHILE ambient temperature ≥ 40 °C
2THEN the ESC case temperature shall remain ≤ 80 °C
3FOR any continuous hover ≥ 30 s
History and ownership
Every version keeps its owner and the reason it changed.
Owner THThermal lead
v4
Lower limit to 80 °CPLafter TEST-121 run 7
v3
Add 30 s hover conditionSEDR-4 design review
v2
Raise limit to 85 °CTHECO-0457
v1
ImportedXthermal_reqs_v3.xlsx
02

Test cases

Once requirements are in, VinciStack drafts the test cases that verify them. Engineers edit them like documents, and every run on every dataset reports back against the requirement it covers.

Generated from requirements
Each requirement gets draft test cases with steps and pass criteria, ready to review.
Requirement
REQ-THM-011

ESC case temperature ≤ 80 °C at 40 °C ambient, any hover ≥ 30 s

Drafting test cases…
TC-THM-011-ADraft

Thermal soak, 40 °C ambient, hover 30 min

  1. Stabilise chamber at 40 °C
  2. Hover at nominal load for 30 min
  3. Pass if ESC_TEMP_1–4 ≤ 80 °C
TC-THM-011-BDraft

Step load to 62 A for 30 s at 40 °C

Accept bothEdit
Edit like a document
Change a step and it is versioned and stays linked to its requirement.
TC-THM-011-ASaved · v2
1Stabilise chamber at 40 °C
2Hover at nominal load for 30 min45 min
3Pass if ESC_TEMP_1–4 ≤ 80 °C
Pass and fail on any dataset
Run the same test cases against flight logs, bench runs and simulations, and see results land per requirement.
Test caseVerifiesFlight run 5Flight run 6Flight run 7Bench 2HIL sim
TC-THM-011-AREQ-THM-011
TC-THM-011-BREQ-THM-011
TC-PWR-042-AREQ-PWR-042
TC-AVN-007-AREQ-AVN-007
15 passed3 failed2 not runREQ-THM-011 failing on flight runs 6 and 7
03

Data analysis

Plot telemetry from any run, let VinciStack find what changed, and pull the right team into the same dataset to look at it together.

Telemetry visualization
Stream channels from YAMCS, DAQs and logs onto one timeline, overlay runs and scrub to any second.
ESC_TEMP_2ESC_TEMP_1, 3, 4RPM_285 °C limit● Live · TEST-121 run 7
Telemetry analysis
Anomalies are found and explained, with the runs that match.
Onsett = 40 s · ESC_TEMP_2 +34 °C
CorrelatedRPM_2 oscillation 40 s later
Also seen inFlight runs 5 and 6
Collaborate on the same dataset
Pin a comment to the exact second, tag a team and assign the check. Everyone looks at the same data.
t = 40 sESC_TEMP_2 · TEST-121 run 7
CT
Controls

RPM_2 starts oscillating here. @Thermal can you check pad contact on ESC 2?

THAssigned to Thermal · due Friday
TH
Thermal

On it. Pad was halved in BOM rev C, pulling the build record now.

04

Observability

See the whole system at once: how it is built, how every requirement traces to its tests and data, what a change would touch, and whether it still fits the budget.

System architecture
Subsystems and the interfaces between them, from your PLM and ICDs.
PowerBattery · BMS PropulsionESC ×4 · Motors ThermalHeatsink · pads AvionicsFlight controller 48 VHeat
Traceability
Requirement to test case to test data, in both directions.
RequirementsTest casesTest data REQ-THM-011TC-THM-011-ARun 7 · fail REQ-PWR-042TC-PWR-042-ARun 3 · pass REQ-AVN-007TC-AVN-007-AHIL sim · pass
Change impact analysis
Check what a change touches across every dependency before you make it.
REQ-THM-011 85 → 80 °CProposed · not yet applied
ESC heatsinkDirect
Motor duty cycleIndirect
Battery placementIndirect
TC-THM-011-A, TC-PWR-042-ARerun
Budget analysis
Mass, power and thermal budgets roll up from every subsystem and update as designs change.
Mass1.79 / 1.90 kg · 6% margin1.83 / 1.90 kg · 4% margin
AirframePropulsionPowerAvionics
Peak power2,480 / 2,600 W · 5% margin
New heatsink adds 40 g. Mass margin now below 5%.
05

Compliance

A data-driven compliance report for every program, ready to share with an authority or keep for internal audit. It shows, from the requirements and the tests that cover them, whether the product is working as it is supposed to.

The report, kept current
As runs finish, the report updates. Every requirement is listed with the test that covers it and the latest result.
HX-4 verification reportPropulsion · as of run 7
REQ-PWR-042Verified · TEST-118
REQ-THM-011Failing · TEST-121
REQ-AVN-012Not yet run
Evidence the product works as specified
Aerospace, space and automotive programs have to show an authority, or their own audit, that the product does what it was specified to do. Each line points at the test and the data.
RequiredESC case ≤ 85 °C at 40 °C ambientREQ-THM-011
Tested byThermal soak, 40 °C, hover 30 minTEST-121
Shown by the dataESC_TEMP_2 peaked at 88.4 °CRun 7 · YAMCS
Share it with an authority
The pack a certification authority or a customer asks for: what was required, what was tested, and what the data showed.
1Verification summary
2Requirement coverage
3Open discrepancies · REQ-THM-011
Share reportReady for the authority
Keep it for the internal audit
The same evidence stays with the program, so a later audit can see why a requirement was called verified, or why it was not.
HX-4 · PropulsionVerification report · run 7
Filed with the program · owner Systems
Linked to TEST-118 and TEST-121
REQ-THM-011 left open · not signed off

Your engineers stay in their tools.

VinciStack connects through MCP. Requirements stay in Jama or Excel, CAD stays in your PLM, test data stays where it is recorded. VinciStack keeps the links between them.

Requirements

  • Excel
  • Jama Connect
  • Polarion
  • IBM DOORS

PLM & CAD

  • Teamcenter
  • Windchill
  • 3DEXPERIENCE
  • Onshape

Simulation

  • MATLAB & Simulink
  • ANSYS
  • dSPACE

Test & telemetry

  • YAMCS
  • NI DAQ
  • CSV & HDF5 logs

Engineering work

  • Jira
  • GitHub
  • GitLab

Communication

  • Slack
  • Microsoft Teams
  • Confluence
Security

Runs inside your trust boundary.

Hardware programs carry export-controlled designs and proprietary test data. VinciStack is built to run where that data already lives.

On-premise deployment

Install on your own servers or private cloud. Connectors run inside your network.

Private inference

Models run on your hardware. Telemetry, CAD and requirements never leave your network.

Defense-grade compliance on request

ITAREARNIST 800-171CUISOC 2 Type IIGDPRCCPA

Bring one failed test run. We'll trace it with you.

In a demo we connect to a sample of your toolchain and walk a real failure from anomaly to root cause to change impact.